Wide Square Mixed Oil Casing Door for Almaty Blocks A wide square mixed oil casing door in Almaty fails at the outer 25 mm of the casing, not at the door. The lintel over a door in a brick or panel wall is uninsulated concrete, so the strip the casing covers sits at 11.2 °C on a −22 °C night while the room is at 21 °C and 50% RH — 94% RH in the boundary layer, above the 80% at which mould grows. By February the outer band on the cold side is a grey-green line no scrubbing removes, and 38% of casings in a 240-apartment development carried it after one winter. The casing was covering the reveal it was asked to cover — on the coldest surface in the apartment. The casing is a thermometer for the wall behind it A 120 mm casing on a 180 mm brick wall covers 45 mm of reveal and 75 mm of wall. The first 45 mm is over the frame, inside the insulation line and warm; the outer 75 mm is over wall, and over a lintel of bare concrete. A 200 mm uninsulated lintel runs at about 11 °C against 16 °C on…